DESCRIPTION
The LDR60K1 integrated laser rangefinder and target marker system is engineered for long-range precision detection. It delivers accurate ranging out to 8,000 meters, alongside effective target illumination reaching 5,000 meters. Developed in accordance with universal international standards, the LDR60K1 ensures broad adaptability and dependable global operational performance.
| Parameter Indicators |
| Module |
LDR60K1 |
| Pump Source |
Laser LD (Laser Diode) Pumping |
| Cooling Method |
Passive cooling, no temperature control |
| Working Mode |
Laser Ranging, Laser target indication |
| Operating Wavelength |
1064nm±3nm |
| Pulse Energy |
≥60 mJ |
| Laser Energy Stability |
Within a single irradiation cycle, the pulse energy fluctuation does not exceed 10% of the average energy. |
| Pulse Width |
≥15 ns±5ns |
| Beam Divergence Angle |
≤0.3mrad |
| Stability of The Laser Optical Axis |
≤0.05mrad |
| Ranging performance |
| Ranging frequency |
1~20Hz |
| Continuous Laser Ranging Time |
5min(1Hz)/1min (5Hz)/20S(20Hz) |
| Minimum measuring distance |
≤300m |
| Maximum measuring distance |
≥12km(Visibility: 16 km, target reflectivity: 0.2, target size: 2.3 m × 2.3 m)
|
| Ranging accuracy |
±1m |
| Rate of successful measurement |
98% |
MECHANICAL DIMENSION(mm)

APPLICATION NOTES
The LDR60K1 is a 1064nm±3nm integrated laser rangefinder and target marker in ranging and target indication modes, diode-pumped with passive cooling and no temperature control. Pulse energy is ≥60mJ with fluctuation within a single irradiation cycle not exceeding 10% of average energy, pulse width ≥15ns±5ns, beam divergence ≤0.3mrad and laser optical axis stability ≤0.05mrad. The specification states a maximum measuring distance of ≥12km for a 2.3m by 2.3m target of reflectivity 0.2 at visibility of 16km, alongside a minimum measuring distance of ≤300m, ±1m ranging accuracy, a 98% success rate and 1~20Hz operation on 5min/1min/20s cycles. The product description additionally quotes ranging out to 8,000 meters with effective target illumination reaching 5,000 meters, which is the pairing a shorter-standoff designation task needs: measure the target, then illuminate it for a semi-active receiver. That combination is suited to observation systems on airborne, shipborne and ground platforms where the 60mJ energy class matches the slant range actually used.
SELECTION GUIDANCE
Select the LDR60K1 when the working standoff sits inside 8,000 meters of measurement and 5,000 meters of illumination, and when site visibility is nearer 16km rather than 23km, since the ≥12km figure is quoted under visibility of 16km with a 0.2 reflectivity target. If more energy is needed for the same standoff, the LDR80K1 states ≥80mJ over ≥10km under visibility of ≥23km, with the same ≤0.3mrad divergence. If the platform is very small, the 40mJ and 25mJ members are described at ≤460g and 380g with minimum measuring distances of ≤100m and ≤120m. Acceptance should record which distance figure the contract refers to, together with the reference target size, reflectivity and visibility, then verify ≥60mJ pulse energy, the 10% in-cycle stability, ≤0.3mrad divergence, ±1m accuracy, the 98% success rate, ≤300m minimum distance, passive cooling without temperature control and 1~20Hz ranging frequency.
FREQUENTLY ASKED QUESTIONS
What ranging and target marking distances does the LDR60K1 deliver?
The LDR60K1 delivers accurate ranging out to 8,000 meters with effective target illumination reaching 5,000 meters, while the specification table lists a maximum measuring distance of >=12km at a visibility of 16 km.
What are the pulse energy and beam divergence angle of the LDR60K1?
The pulse energy is >=60 mJ and the beam divergence angle is <=0.3mrad.
What is the ranging accuracy and ranging frequency of the LDR60K1?
Ranging accuracy is +/-1m over a ranging frequency of 1~20Hz.
What is the minimum measuring distance and measurement success rate of the LDR60K1?
The minimum measuring distance is <=300m and the rate of successful measurement is 98%.
ORDERING INFORMATION
Is there a minimum order quantity?
There is no minimum order quantity. Single units and evaluation samples are accepted.
What is the sample lead time?
Samples are shipped within 1 week after order confirmation.
What is the batch production lead time?
Batch production is delivered within 1 month after order confirmation.