DESCRIPTION
Leveraging Time-of-Flight (TOF) technology, this 905nm laser ranging module realizes high-precision distance measurement through calculating the round-trip travel time of laser beams. It offers a measurement range spanning 5 to 1500 meters and comes equipped with a UART (TTL_3.3V) interface, supporting both single-shot and continuous ranging functions.
TECHNICAL SPECIFICATIONS
| Performance Indicators |
|
Eye safety class
|
Class 1(IEC 60825-1)
|
|
Laser wavelength
|
905±10nm
|
|
Laser divergence angle (typical)
|
3×6mrad
|
|
Average laser power
|
8.43mW
|
|
Laser pulse width
|
40ns
|
|
Receiver field of view
|
~8mrad
|
|
Maximum range
(Visibility ≥ 6Km)
|
≥1500m @70% reflectivity, building targets
|
|
Minimum range
|
5m
|
|
Ranging accuracy
(Construction target)
|
d≤200m:±0.7m
d>200m:±(0.7+0.0004*d)m (d represents distance, in meters)
|
|
Measurement frequency
|
1~3Hz
|
|
Accuracy rate
|
≥98%
|
|
False alarm rate
|
≤1%
|
| Electrical Specifications |
|
Baud rate
|
15200bps (factory setting)/57600bps/38400bps/9600bps
|
|
Interface type
|
UART(TTL_3.3V)
|
|
Supply voltage
|
DC 3.3±0.1V
|
| Standby power consumption |
≤0.5mW (Power on pulled low)
|
|
≤0.35W (Power on pulled high)
|
|
Operating power consumption
(+3.3Vin)
|
≤1.5W@25℃
|
|
≤1.75W@70℃
|
|
≤1.38W@-20℃
|
|
Startup time
|
≤550ms
|
| Physical characteristics |
|
Weight
|
11±0.5g
|
|
Dimensions
|
26×25×14.5mm(L×W×H)
|
|
Shock
|
1200g,1ms
|
|
Vibration
|
5~50~5 Hz, 1 octave/min, 2.5g
|
| Environmental adaptability |
|
Operating temperature
|
-20~+70℃
|
|
Storage temperature
|
-25~+75℃
|
|
Reliability
|
MTBF≥1500h
|
Note: Visibility refers to visibility in fog and haze weather, and the impact is greater in sandstorm weather.
OUTLINE DIMENSION(mm)
Mechanical Interface and Center of Mass Position

Structural Installation
The recommended dimensions of the mounting bracket are as follows:

Installation Diagram:

The thread length of the countersunk head screw must not exceed 3.5mm.
PIN INTERFACE
Interface Type: UART (TTL_3.3V)
Connector Model: HC-0.8-6PWT
|
Pin
|
Definition
|
Description
|
Color
|

|
|
1
|
GND
|
Ground wire
|
Green
|
|
2
|
Power Supply
|
3.3V DC power supply
|
Yellow
|
|
3
|
NC
|
No connection (NC)
|
Orange
|
|
4
|
TTL_TXD
|
Serial port transmitter, TTL_3.3V level
|
Red
|
|
5
|
TTL_RXD
|
Serial port receiver, TTL_3.3V level
|
Brown
|
|
6
|
Enable Pin
|
Low level to power on
|
Black
|

The 1500m Semiconductor Pulse Rangefinder Module leverages 905nm TOF technology for precise 5–1500m distance measurement. Featuring UART (TTL_3.3V) interface, single-shot/continuous ranging, direct TTL-to-MCU connectivity, PC configuration software, and standardized command protocols.
APPLICATION NOTES
This module measures 5 m to ≥1500 m against building targets of 70% reflectivity at visibility of ≥6 km, at 905 ± 10 nm, Class 1 to IEC 60825-1 and 1~3 Hz, with ±0.7 m accuracy to 200 m and ±(0.7 + 0.0004 x d) m beyond. Single-shot and continuous ranging over UART (TTL_3.3V), direct TTL-to-MCU connectivity, PC configuration software and standardized command protocols make it suited to work where the host controller is already fixed and only the command set has to be mapped.
The module is 11 ± 0.5 g in 26 x 25 x 14.5 mm, fed from 3.3 ± 0.1 V, with ≤0.35 W standby when the enable is held high and ≤1.5 W at 25 °C, ≤1.75 W at 70 °C and ≤1.38 W at -20 °C, so it is typically used where ambient temperature excursions are part of the qualification plan. Shock of 1200 g for 1 ms, 2.5 g vibration, -20 °C to +70 °C operation and MTBF ≥1500 h fit outdoor airborne and vehicle payload duty.
SELECTION GUIDANCE
Select this module where a 1.5 km envelope on 70% targets, 11 g and a 3.3 V rail are enough. Where the standoff has to reach 2 km on the same targets, the 2000 m member keeps the 3.3 V rail, the 1~3 Hz cadence and the same 26 x 25 x 14.5 mm envelope; where 3.3~5 V supply flexibility and ≤0.85 W operation matter more than reach, the 1000 m member is the closer fit; for Class 1 operation at longer standoff in shared airspace, 1535 nm modules are the class to evaluate.
At acceptance, verify ≥1500 m under visibility ≥6 km and 70% reflectivity, the 5 m minimum range, the accuracy formula either side of 200 m, an accuracy rate of ≥98% with a false alarm rate of ≤1%, the 1~3 Hz rate in both single-shot and continuous modes, ≤550 ms startup, standby and operating power at 25 °C, 70 °C and -20 °C, the ≤0.5 mW figure with the enable pulled low, UART at the configured baud rate, and MTBF ≥1500 h.
FREQUENTLY ASKED QUESTIONS
What is the maximum measurement range of the 905nm Laser Rangefinder Module 1.5km?
The specified maximum range is ≥1500 m at 70% reflectivity against building targets, with visibility ≥6 km. The minimum range is 5 m.
What ranging accuracy does the 1500 m module achieve?
For targets at d≤200 m the accuracy is ±0.7 m, and for d>200 m it is ±(0.7+0.0004*d) m, where d is the distance in meters.
Which interface and baud rate does it support?
It provides a UART (TTL_3.3V) interface on the HC-0.8-6PWT connector, with 15200bps as the factory setting and 57600bps, 38400bps or 9600bps also available.
What is the measurement frequency and accuracy rate?
Measurement frequency is 1~3 Hz, with an accuracy rate of ≥98% and a false alarm rate of ≤1%.
What are its weight and dimensions?
The module weighs 11±0.5 g and measures 26×25×14.5 mm (L×W×H).
ORDERING INFORMATION
Is there a minimum order quantity?
There is no minimum order quantity. Single units and evaluation samples are accepted.
What is the sample lead time?
Samples are shipped within 1 week after order confirmation.
What is the batch production lead time?
Batch production is delivered within 1 month after order confirmation.
RELATED TECHNICAL GUIDES