DESCRIPTION
LRF50H-02 is a mid-range, high-frequency laser ranging module that comes with an integrated coaxial aiming light (which can be switched freely), making it easier for users to align and install. It operates at a 905nm laser wavelength and has strong resistance to ambient light, ensuring stable performance in various indoor and outdoor settings. Thanks to its high-frequency measurement function, it can acquire data quickly with millimeter-level precision, rendering it suitable for high-demand applications like industrial automation, robot navigation, construction surveying, and security monitoring.
TECHNICAL SPECIFICATIONS
|
#
|
Model
|
LRF50H
|
|
1
|
Range
|
0.05m~50m (90%reflectivity), 0.05m~15m (10%reflectivity)1
|
|
2
|
Frequency
|
20Hz~10KHz (Default: 1KHz)
|
|
3
|
Accuracy
|
±5cm(<10m) , 1%(≥10m)(2σ)
|
|
4
|
Repeatability
|
±5cm
|
|
5
|
Ambient Light Immunity
|
45m@100KLux2
|
|
6
|
Central Wavelength
|
905nm
|
|
7
|
Photobiological Safety
|
Class 1
|
|
8
|
FOV
|
about 4mrad
|
|
9
|
Wavelength for Indication
|
650nm (visible red light)
|
|
10
|
Photobiological Safety for Indication
|
Class 2
|
|
11
|
Supply Voltage
|
9~36VDC
|
|
12
|
Peak Current
|
24V@100mA
|
|
13
|
Average Current
|
24V@34mA
|
|
14
|
Average Power Consumption
|
0.8W
|
|
15
|
Communication Interface
|
UART
|
|
16
|
Protection Level
|
N/A
|
|
17
|
Dimension
|
38 x 20 x 30 mm
|
|
18
|
Weight
|
15±2g
|
|
19
|
Operating Temperature
|
-20℃~+60℃
(No condensation,indicator red light automatically turns off when under -20℃)
|
|
20
|
Wire Specification
|
5-pin 1.25mm terminal, specification M1250V-05P, with 50cm tinned loose wire
|
|
21
|
Customization
|
available in appearance / structure / output protocol
|
(Note: 1. This parameter was measured at 25°C in an indoor environment.
2. This parameter was measured with a 90% reflector in an outdoor environment at 25°C.)
OUTLINE DIMENSION(mm)

PIN INTERFACE
 |
|
No.
|
Definition / Wire Color
|
User Interface
|
|
1
|
9~36V (Red)
|
External Power +
|
|
2
|
GND (Black)
|
GND
|
|
3
|
GND (Yellow)
|
GND
|
|
4
|
TX (Green)
|
RX
|
|
5
|
RX (Blue)
|
TX
|
APPLICATION NOTES
The LRF50H covers 0.05–50 m on 90% reflectivity targets and 0.05–15 m on 10% reflectivity targets at 905 nm with Class 1 eye safety, and adds an integrated coaxial aiming light at 650 nm (Class 2) that can be switched freely so the optical axis is aligned during installation. A 20 Hz to 10 kHz repetition range with a 1 kHz default, ±5 cm accuracy below 10 m, 1% at and beyond 10 m (2σ) and ±5 cm repeatability give a fast data stream at short standoff.
At 15 ± 2 g in a 38 x 20 x 30 mm housing, 0.8 W from 9~36 VDC and a UART link, it is suited to industrial automation, robot navigation, construction surveying and security monitoring, where the sensor is fitted to a machine or fixture and boresighting has to be verified by eye. Ambient light immunity of 45 m at 100 KLux keeps outdoor daytime work usable, and the operating range is -20 °C to +60 °C without condensation, with the red indicator switching off automatically below -20 °C.
SELECTION GUIDANCE
Select the LRF50H where the visible aiming aid removes a separate alignment fixture, or where 50 m with ±5 cm at close range is the right resolution. If the envelope has to grow to 100 m, 200 m or 300 m, the higher-range family members omit the 650 nm indicator and should be chosen on reach alone; if a visible Class 2 beam is not acceptable in the installation, the 905 nm single-point modules offer Class 1 only, at shorter ranges.
At acceptance, verify 50 m at 90% and 15 m at 10% reflectivity, the 45 m at 100 KLux immunity figure, accuracy of ±5 cm below 10 m and 1% at and beyond 10 m (2σ), ±5 cm repeatability, the 20 Hz to 10 kHz range with its 1 kHz default, the 650 nm aiming light including its switch-off behaviour, 0.8 W average power at the stated current figures, and the condensation-free operating condition.
FREQUENTLY ASKED QUESTIONS
What is the measuring range of the LRF50H?
It measures 0.05m~50m at 90% reflectivity and 0.05m~15m at 10% reflectivity, with an ambient light immunity of 45m@100KLux.
What accuracy and repeatability does the LRF50H provide?
Accuracy is ±5cm(<10m) and 1%(≥10m)(2σ), and repeatability is ±5cm.
Does the LRF50H have an aiming light?
Yes, it has an integrated coaxial aiming light that can be switched freely, with a wavelength for indication of 650nm (visible red light) and Class 2 photobiological safety for indication.
What is the measurement frequency of the LRF50H?
Its frequency is 20Hz~10KHz with a default of 1KHz.
What supply voltage, power consumption and interface does the LRF50H use?
It operates on 9~36VDC with an average power consumption of 0.8W over UART, and the module measures 38 x 20 x 30 mm with a weight of 15±2g.
ORDERING INFORMATION
Is there a minimum order quantity?
There is no minimum order quantity. Single units and evaluation samples are accepted.
What is the sample lead time?
Samples are shipped within 1 week after order confirmation.
What is the batch production lead time?
Batch production is delivered within 1 month after order confirmation.
RELATED TECHNICAL GUIDES
Further ERDI Laser engineering references on 905 nm short-range LiDAR and ranging sensors: